DESCRIPCIÓN
<p> CUENTA CON CAPACIDAD DE PRODUCCIóN DE CAMARóN VANNAMEI, TILAPIA BAGRE Y OTRAS ESPECIES, CON UNA SUPERFICIE TOTAL DE 20 HECTáREAS INTENSIVAS. UBICADO EN CHINá- CHULBAC, CAMPECHE.<br>DATOS TECNICOS CHULBAC:<br>1.- NUMERO DE ESTANQUES Y TIPOS: 10 ESTANQUES DE PRECRIA Y 20 ESTANQUES DE ENGORDA.<br>2.- DIMENSIONES DE LOS ESTANQUES CON PROFUNDIDAD PROMEDIO: 10 ESTANQUES DE PRECRIA. AREA TOTAL DE PRECRIA 12,000 M2 (DISTANCIA A EJES 40X36, AREA HIDRAULICA (1,200M2), ALTURA DE BORDO PROMEDIO 1.80 MTS, PROFUNDIDAD COLUMNA DE AGUA PROMEDI0 1.40 MTS) Y 20 ESTANQUES DE ENGORDA. AREA TOTAL DE ENGORDA 140,000 M2 (DISTANCIA A EJES 42X182, AREA HIDRAULICA (7,000M2), ALTURA DE BORDO PROMEDIO 1.70 MTS Y PROFUNDIDAD COLUMNA DE AGUA PROMEDIO 1.30 MTS. <br>3.- EQUIPO DE AIREACION DISPONOBLE (HP Y TIPO DE AIREADOR) <br>4.- SE REQUIERE ANALISIS DE ALCALINIDAD DEL AGUA EN MG/L O PPM (SEGúN LO ULTIMO QUE MANEJARON FUERON 2 PPM)<br>5.- INSTALACIONES DISPONIBLES BODEGAS, OFICINAS, LABORATORIO, ETC.<br>6.- CAPACIDAD DE BOMBEO DE LAS BOMBAS DEL POZO (LT / SEG) Y 100LTS / SEG, CON BOMBA VERTICAL SUMERGIBLE DE 10 PULGADAS (FALTA VERFICAR LOS HP DEL MOTOR)<br>7.- CAPACIDAD DE REBOMBEO: 30 LTS / SEG CON BOMBA DE 6. (SI SE INSTALA)<br>8.- VOLUMEN DE REBOMBEO EN FUNCION DEL ESPEJO DE AGUA: LAGUNA DE 40 X 360 X 1.0 = 14,400 M3. SERIA UN 10 % DE LOS ESTANQUES DE ENGORDA SIEMPRE Y CUANDO SE MEJORE LA CALIDAD DEL AGUA DE LA LAGUNA DE SEDIMENTACION CON PROBIOTICOS.<br>9.- PORCENTAJE DE RECAMBIO DISPONIBLE EN 24 HORAS: 8000 M3 POR 24 HORAS DE BOMBEO, 100 % DE UN ESTANQUE DE ENGORDA Y 5 % DE LOS 20 ESTANQUES DE ENGORDA.<br>10.- CAPACIDAD INSTALADA DE LAS PLANTAS DE ENERGIA ELECTRICA (KVA).</p><p><br></p><p><br></p><p><span style="font-weight: bold;">Aquaculture Farm for Sale – Chulbac, Campeche</span></p><div><br></div><div>Specialized in the production of Vannamei shrimp, tilapia, catfish, and other species, with a total surface area of 20 hectares (intensive system).</div><div><br></div><div>???? Location: China–Chulbac, Campeche</div><div><br></div><div><br></div><div><br></div><div>???? <span style="font-weight: bold;">Technical Data – Chulbac Facility</span></div><div><span style="font-weight: bold;"><br></span></div><div><span style="font-weight: bold;">Number and Type of Ponds</span></div><div><br></div><div>Pre-nursery ponds: 10</div><div><span style="font-size: 14px;">Grow-out ponds: 20</span></div><div><br></div><div><span style="font-weight: bold;">Pond Dimensions and Average Depth</span></div><div><br></div><div><span style="font-weight: bold;">Pre-nursery ponds:</span></div><div><br></div><div>Total pre-nursery area: 12,000 m²</div><div><span style="font-size: 14px;">Pond spacing: 40 m x 36 m</span></div><div>Hydraulic area per pond: 1,200 m²</div><div>Average berm height: 1.80 m</div><div>Average water column depth: 1.40 m</div><div><span style="font-weight: bold;"><br></span></div><div><span style="font-weight: bold;">Grow-out ponds:</span></div><div><span style="font-weight: bold;"><br></span></div><div>Total grow-out area: 140,000 m²</div><div><span style="font-size: 14px;">Pond spacing: 42 m x 182 m</span></div><div><span style="font-size: 14px;">Hydraulic area per pond: 7,000 m²</span></div><div><span style="font-size: 14px;">Average berm height: 1.70 m</span></div><div><span style="font-size: 14px;">Average water column depth: 1.30 m</span></div><div><br></div><div><span style="font-weight: bold;">Aeration Equipment</span></div><div><br></div><div>Aerators available (specifications to be confirmed: HP and type)</div><div><br></div><div><span style="font-weight: bold;">Water Alkalinity</span></div><div><br></div><div>Last recorded: 2 ppm (mg/L)</div><div><br></div><div><span style="font-weight: bold;">Facilities Available</span></div><div><br></div><div>Warehouses</div><div><span style="font-size: 14px;">Offices</span></div><div><span style="font-size: 14px;">Laboratory</span></div><div><br></div><div><span style="font-weight: bold;">Main Water Pump Capacity</span></div><div><br></div><div>100 liters/second, with a 10-inch vertical submersible pump</div><div><span style="font-size: 14px;">(Motor HP to be verified)</span></div><div><span style="font-weight: bold;"><br></span></div><div><span style="font-weight: bold;">Re-pumping Capacity</span></div><div><br></div><div>30 liters/second, with a 6-inch pump (installation required)</div><div><span style="font-weight: bold;"><br></span></div><div><span style="font-weight: bold;">Re-pumping Volume Based on Water Mirror</span></div><div><br></div><div>Sedimentation lagoon: 40 m x 360 m x 1.0 m = 14,400 m³</div><div><span style="font-size: 14px;">Represents 10% of the total grow-out pond volume, pending water quality improvement with probiotics</span></div><div><span style="font-weight: bold;"><br></span></div><div><span style="font-weight: bold;">Water Exchange Capacity (per 24 hours)</span></div><div><br></div><div>8,000 m³ in 24 hours of pumping</div><div><span style="font-size: 14px;">Equals 100% exchange for one grow-out pond or 5% for all 20 grow-out ponds</span></div><div><br></div><div><span style="font-weight: bold;">Installed Electrical Power Plant Capacity</span></div><div><br></div><div>(KVA to be specified)</div><div><br></div><p>
</p>